PROPERTY |
VALUE |
TEST METHOD |
|
Typical 8" Block Cores Empty |
Cores Filled With THERMCO® Foam Insulation |
Density of Block |
|
1) Thermal
Conductivity
1" Thickness at 75° F mean
35° F mean
3-1/2" Thickness at 75° F mean |
.224 (4.5 R)*
.212 (4.7 R)
.066 (15.3 R) |
ASTM-C-177 |
R
U |
R U |
lb./cu/ft. |
|
3.10
.32 |
14.29
.07 |
60 lb. |
|
2.92
.34 |
11.27
.09 |
80 lb. |
|
2.60
.38 |
9.10
.11 |
100 lb. |
|
2) Fire Safety
Flame Spread
Smoke Developed |
5
50-100 |
ASTM-E-84-89a |
|
2.30
.43 |
6.70
.15 |
120 lb. |
|
|
|
3) Density,
lbs./ft.3 |
.70 |
ASTM-D-1622 |
|
|
4) Shrinkage-
normal. present |
1.86 |
HUD-MB-74 |
|
|
|
|
|
5) Fire Wall Rating |
4 hrs. |
ASTM-E-119-88 (Equivalent to
UL901 and UL905) |
INSULATING VALUES FOR 12"
BLOCK WALLS |
|
Typical 12" Block Cores Empty |
Cores Filled With THERMCO® Foam Insulation |
Density of Block |
|
6) Corrosion
Aluminum, Copper
Steel, Galvanized Steel |
less than
1g pitting |
HUD-MB-74 |
R
U |
R U |
lb./cu/ft. |
|
4.20
.24 |
20.01
.05 |
60 lb. |
|
7) Acoustic
Properties |
8" CMU Wall
STC=52
12" CMU Wall
STC=54 |
ASTM-E-90-97 |
3.40
.29 |
16.70
.06 |
80 lb. |
|
2.90
.34 |
12.50
.08 |
100 lb. |
|
2.60
.38 |
10.0
.10 |
120 lb. |
|
|
|
|
R values calculated
using parallel heat flow
R values taken from
National Concrete Masonry Association
|
|
* R means
resistance to heat flow; the higher the R value, the
greater the insulating power.
Limitations: This material is not intended
for use with temperatures
exceeding 190° for prolonged
periods of time. The
foam will not support a compressive load and should
not be used for floatation, overhead applications or
underground as a vapor barrier. |